Resin floor glossary: the words on a flooring bid

Written for someone reading a flooring bid or data sheet for the first time. Each definition comes from a published source, and the source is named.

First published November 27, 2026 · Last reviewed November 27, 2026

A flooring bid mixes chemistry, concrete and safety terms. These are the ones that come up most. Where a definition leans on one document, the document is named. Figures belong to the product or document named beside them, not to every floor.

Resins and chemistry

Resinous flooring (resin floor)
A floor that goes down as a liquid and hardens in place. The Construction Specifier also calls it fluid-applied or poured-in-place flooring.
MMA (methyl methacrylate)
The liquid resin an acrylic floor is made from. NIOSH describes it as a colorless liquid with an acrid, fruity odor. Sika says each component of its MMA freezer system cures fully in an hour or less, and that it may take longer below freezing. See acrylic vs epoxy and odor and ventilation.
Acrylic and PMMA
Other names for the same family of floors. Sika calls its MMA primer a reactive acrylic primer, and Sika's UK site calls its Pronto MMA floors PMMA (polymethyl methacrylate) flooring systems. EPA notes that methyl methacrylate is used to make methacrylate plastics such as Plexiglas.
Epoxy
ACI's concrete terminology defines epoxy as a thermosetting polymer made by reacting epoxy resin with a compatible hardener. The Construction Specifier puts a typical cure at 8 to 12 hours to reach about 95 percent and 7 to 10 days to reach 100 percent. It adds that epoxy is not UV stable and will yellow under UV light.
Polyurethane (urethane)
A resin most commonly made by reacting isocyanates with polyols. The Construction Specifier says urethane coatings are typically applied thin, as a final top coat or seal coat, and are known for abrasion resistance, chemical resistance and UV stability.
Urethane cement (cementitious urethane)
A urethane modified with cement. The Construction Specifier says it withstands thermal shock of up to 240°F and is used as the body of the hybrid floors often found in commercial kitchens.
Polyaspartic
A fast-curing resin, similar to polyurethane, used mostly as a broadcast coat or top coat. The Construction Specifier gives a cure of one to four hours and calls it UV stable. It warns that a polyaspartic may not accept a later recoat without aggressive mechanical preparation.
Hardener, initiator, catalyst (BPO)
ACI defines a hardener as the part of a two-component coating that causes the resin to cure. For MMA it is a white powder containing benzoyl peroxide, which Sika calls an initiator, Flowcrete a catalyst and Duraamen a hardener made with BPO. Sika's primer sheet calls for more of it as the temperature drops.

Systems and layers

Mil
One thousandth of an inch. Sherwin-Williams's conversion chart gives 1/8 inch as 125 mils and 1/4 inch as 250 mils.
Primer
The first coat on the prepared concrete. Sika says its MMA primer is thin enough to penetrate and reinforce the concrete, and calls it the first step of every floor system in that line.
Body coat (base coat)
The thick middle layer of a floor system. On Sika's MMA freezer system it is a self-leveling coat applied 3/16 inch thick. Fosroc gives a base coat's purpose as protecting the floor from thermal, mechanical and chemical stress and holding the aggregate.
Broadcast
Scattering aggregate into a wet coat so that it cures embedded in the surface. LATICRETE's quartz sheet describes broadcasting to refusal or rejection: the quartz rains down until no wet resin shows, and the loose excess is swept up after cure. How this sets the floor's grip is covered in slip resistance.
Quartz and flake
Two decorative broadcast materials. LATICRETE describes its quartz as uniformly sized quartz granules with a color coating, and Sherwin-Williams lists decorative vinyl flake and decorative quartz among its broadcast finishes. Sika says the quartz in its MMA freezer system gives a non-skid texture.
Top coat, seal coat and grout coat
The coat or coats applied over the broadcast. Fosroc gives the top coat's purpose as sealing the surface and balancing slip rating against cleanability. LATICRETE's quartz sheet requires a grout coat, a top coat or both. See slip resistance.
Self-leveling
A resin mix fluid enough to flow out over the slab and find its own level, as a glossary from flooring contractor Surface Solutions puts it. Sika's MMA freezer system is sold as a self-leveling floor.
Mortar (troweled floor, screed)
Resin mixed with aggregate and placed with a trowel. ACI defines epoxy mortar as a mixture of epoxy resin, hardener and fine aggregate. Sika lists one trowel-grade urethane cement screed at 1/4 to 1/2 inch thick.
Cove base
The floor turned up the wall on a curve. Sherwin-Williams says an integral cove makes a seamless, watertight transition from floor to wall and removes the sharp corner where dirt and bacteria collect. The Construction Specifier gives the usual heights as 4 or 6 inches, with 6 for commercial kitchens and other wet areas. See what the food rules say about floors.
Coefficient of friction (COF, DCOF)
A number for grip. TCNA defines the dynamic coefficient of friction as the force needed to keep one surface sliding over another, divided by the weight of the sliding object. TCNA adds that it does not predict whether a person will slip. See slip resistance.

Surface preparation and joints

CSP (concrete surface profile) and ICRI 310.2R
How rough the prepared concrete is, measured from the peaks of the surface to the valleys. ICRI guideline 310.2R grades it from CSP 1, nearly flat, to CSP 10, very rough. The data sheet for each product names the number it needs. See floor prep and moisture.
Shot blasting
A machine throws small steel particles at the slab at high speed. Sherwin-Williams says the process removes surface contamination, adds profile and vacuums the concrete clean in one dry pass.
Diamond grinding
Floor grinders fitted with diamond abrasives. Sherwin-Williams says they can produce a wide range of surface profiles and are also used to remove existing coatings and adhesives.
Scarifying
Stonhard describes a concrete scarifier as spinning blades on a rotating drum that chip away the upper layers of concrete.
Acid etching
ACI defines it as removing a cementitious surface through controlled dissolution, for example to roughen a smooth surface before a cementitious coating. Stonhard says it is no longer recommended for commercial and industrial floors, and Sika's MMA system sheet says not to use it.
Laitance
A weak layer at the top of a slab. ACI defines it as weak material from cement and aggregate fines, carried to the surface when fresh concrete bleeds or left there during placement. Stonhard says it has to be removed to get a good bond.
Curing compound
ACI defines it as a liquid applied to newly placed concrete to slow the loss of water. Sherwin-Williams lists curing compounds among the bond-inhibiting contaminants that must come off before a resin floor goes down.
Control joint (contraction joint)
A groove formed, sawed or tooled into the concrete to create a weakened plane, so that cracking happens there (ACI). Sherwin-Williams treats these as non-moving joints and fills them flush with a rigid joint filler.
Expansion joint and isolation joint
Separations between adjacent sections of a concrete structure that let them move (ACI). Sherwin-Williams classes expansion, isolation and construction joints as moving joints.
Honoring a joint
Carrying a moving joint up through the new floor. Sherwin-Williams says moving joints must be honored by saw cutting through the finished floor system and filling the cut with a flexible joint sealant. It warns that not honoring them can lead to cracks in the surface.

Moisture

MVER and ASTM F1869 (calcium chloride test)
MVER is the moisture vapor emission rate: the pounds of moisture a 1,000 square foot area of slab gives off in 24 hours. ASTM F1869 measures it with anhydrous calcium chloride, which Sherwin-Williams says sits under a sealed dome on bare concrete for 60 to 72 hours. ASTM notes that the result only reflects the floor at the time of the test. See floor prep and moisture.
ASTM F2170 (relative humidity test)
Probes set in holes drilled into the slab read the relative humidity inside the concrete. Sherwin-Williams gives the hole depth as 40 percent of the slab's thickness. ASTM notes that the result shows the slab's moisture condition only at the time of the test.
Moisture mitigation
A different system or an extra layer used when a slab tests too wet. Stonhard says a moisture-mitigation system is installed when relative humidity readings are high. Sika's MMA primer sheet calls for a different base coat at least 1/8 inch thick when its meter limit is exceeded.
Vapor barrier
ACI defines it as a membrane under a concrete floor slab on the ground that slows the passage of water vapor. Sika's MMA primer sheet says one should be in place for slab-on-grade work.
Dew point
The temperature the air must be cooled to for its relative humidity to reach 100 percent (National Weather Service). Sika's sheets require the slab to be at least 5°F above the dew point to reduce the risk of condensation.

Cure and schedule

Pot life
The time after mixing during which the material can still be applied without harming the result (ACI). Sika lists about 10 to 15 minutes at 75°F for its MMA primer and about 25 minutes at 68°F for one of its epoxies.
Cure time and return to service
How long a coat takes to harden, and when the finished floor can go back into use. Sika lists 35 to 60 minutes at 75°F for its MMA primer. For one of its epoxies at 68°F it lists about 12 hours to foot traffic, 2 days to light traffic and 7 days to full cure. See acrylic vs epoxy.
Recoat window
The earliest and latest times the next coat can go on. One Sika epoxy sheet sets it at 8 to 24 hours at 68°F. Sika's MMA primer sheet says its MMA products have no maximum recoat window.

Things that go wrong

Thermal shock
Sherwin-Williams defines it as the physical stress on a material that undergoes a sudden and extreme change in temperature. Its example is a plant floor washed down with 185°F water after running near freezing. Damage follows when the floor expands and contracts at a rate significantly different from the concrete under it. See freezer and cooler floors.
Osmotic blistering
Blisters that rise in a finished floor. Stonhard explains that moisture trapped in the slab creates osmotic pressure that pushes against the flooring from below. Sherwin-Williams adds that salt contamination in the concrete may contribute.
Outgassing and pinholes
Air leaving the concrete as it warms. Sherwin-Williams says air pushed through a wet coat is caught in the setting resin as tiny craters, often with a pinhole in the center. It advises coating when the slab is at its warmest and about to cool.
Amine blush
An epoxy problem. Sherwin-Williams describes it as a reaction between water, carbon dioxide and the amine component of an epoxy coating that leaves a sticky, oily or waxy surface. It can act as a bond breaker between coats.

Safety and paperwork

SDS (safety data sheet)
The hazard document for a chemical product, formerly called an MSDS. OSHA's Hazard Communication Standard requires the maker, distributor or importer to provide one for each hazardous chemical, in a 16-section format. Employers must keep them readily accessible to employees.
TDS, PDS and system data sheet
The maker's technical sheet for one product (a technical or product data sheet) or for a whole build of layers (a system data sheet). It carries the coverage rates, temperature limits, pot life and cure times. Sika's sheets tell users to read the current label, product data sheet and safety data sheet before each use.
VOC (volatile organic compound)
EPA describes VOCs as compounds with a high vapor pressure and low water solubility, and lists paints among the products that give them off.
Flash point
The lowest temperature at which a liquid gives off enough vapor to form an ignitable mixture with air (OSHA, 29 CFR 1910.106). NIOSH lists a flash point of 50°F for methyl methacrylate, and Sika's sheets call uncured MMA resins flammable liquids.
PEL (permissible exposure limit)
An OSHA limit on a worker's exposure to a chemical. NIOSH lists the OSHA PEL for methyl methacrylate as 100 ppm as a time-weighted average, a level not to be exceeded over any 8-hour shift of a 40-hour week. OSHA itself says many of its PELs are outdated. See odor and ventilation.
Air changes per hour (ACH)
The volume of air moved through a space in an hour, divided by the volume of the space (CDC's infection-control glossary). Sika's MMA primer sheet calls for the air to be exchanged at least seven times per hour during indoor work. See odor and ventilation.
Negative pressure
A pressure difference between two adjoining spaces, set so that air flows into the room and is kept from flowing out. That is how CDC's infection-control glossary defines it. A Construction Canada article describes a negative pressure containment system for MMA floor installations, built from a physical barrier, sealed HVAC return vents, fans and filters.
Limits of this page: these are short definitions and they leave things out. This page is not safety or legal advice. Each figure belongs to the product or document named with it. The data sheet for the exact product on your bid is the one that counts.