Where water, oil or grease reach the floor regularly, a seamless resin floor is normally specified with texture. A 2003 Plant Services article co-written by a Sherwin-Williams vice president says so. How much texture is a choice, and it has a cost in cleaning.
How texture gets into the floor
Stonhard describes three routes: aggregate embedded in the coating, a non-slip additive mixed into the resin, or a clear non-slip sealer over the finished floor.
The first is called a broadcast. On Sika's data sheet for an MMA freezer floor, the crew throws quartz into the wet base coat until no wet spots show. After it cures they sweep and vacuum off the loose grains, then apply a clear top coat.
The second uses loose grit, sprinkled onto a wet coat or blended into it, as a Floorguard Products reference sheet describes. Grit is sized by mesh number, and a lower number is coarser. Sherwin-Williams describes aluminum oxide from 220 mesh, a slight texture, to 46 mesh, an extremely aggressive one.
The top coat decides how much grit you feel. The Plant Services article says a single thin coat follows the profile of the grains, while grout coats and top coats of clear epoxy or urethane fill it in. LATICRETE says a second top coat may be used when a smoother surface is wanted. Sika's MMA sheet makes its second top coat optional and notes that coverage rates vary with the desired texture.
Grip against cleaning
Makers are open about the trade. A Sherwin-Williams article says that of slip resistance, cleanability and durability, improving one often comes at the expense of the others. Stonhard warns that excessive texture can trap dirt and debris and make the floor harder to clean. A Fosroc technical bulletin from Australia says the more aggregate applied, the harder the surface is to clean. It adds that a lighter broadcast of a larger aggregate is easier to clean and can still give good slip resistance.
A textured floor is cleaned differently. The Plant Services article says the first step is to "put away the mops", because mops shed fibers on abrasive surfaces and spread grease and oil films. Without an effective cleaning procedure, it warns, the extra friction is quickly lost. There is more in cleaning and maintenance.
The floor is only part of the answer. A Sika white paper sets cleaning, workplace behavior and footwear alongside drainage and the floor's surface profile.
What OSHA requires
The OSHA rule is 29 CFR 1910.22, the general requirements for walking-working surfaces. Workroom floors must be kept clean and, as far as feasible, dry. Where wet processes are used, drainage must be maintained and dry standing places such as platforms and mats provided where feasible. The employer must inspect surfaces regularly and correct or guard a hazard before employees use the surface again. The section as OSHA publishes it contains no friction number.
In an interpretation letter dated March 21, 2003, OSHA wrote that it had no standard mandating a particular coefficient of friction (COF) for walking and working surfaces. The letter traces the often-quoted 0.5 to a non-mandatory appendix in a rulemaking proposal, where it was recommended as a guide and described as not an absolute value. OSHA has since archived the letter. Its notice says the letter may no longer represent OSHA policy and is kept as historical content. The figure still circulates. Sika's white paper states it as an OSHA recommendation.
ANSI A326.3 and the 0.42 figure
ANSI A326.3 is an American National Standard for measuring the dynamic coefficient of friction (DCOF) of hard surface flooring materials. The Tile Council of North America (TCNA) offers it as a free download. It was released in 2017 and revised in 2021. TCNA's FAQ says its classifications are not just for ceramic tile, and Sherwin-Williams says it can be applied to resinous flooring.
The 0.42 comes from this standard. As Sherwin-Williams's guide quotes it, flooring for level interior spaces expected to be walked on when wet with water must measure 0.42 or more, wet, unless the manufacturer declares otherwise. The same passage adds that floors measuring 0.42 or more are not necessarily suitable for all projects.
TCNA's FAQ is plain about the limits. DCOF helps compare surfaces. It does not predict whether a person will slip, and it is not the same thing as slip resistance. The FAQ lists other factors, among them the shoe sole and its wear, contaminants, whether the floor is flat or inclined, how it is used and maintained, and how liquids drain.
The 2021 revision sorts products into five use categories: Interior Dry, Interior Wet, Interior Wet Plus, Exterior Wet, and Oils/Greases. In the FAQ's table the last three carry no fixed number. The manufacturer declares the product for that use. This matters in a kitchen. Sherwin-Williams's summary puts back-of-house restaurant floors and food preparation areas with grills or deep-fry equipment under Oils/Greases, and adds that without a declaration a wet DCOF of at least 0.55 is generally accepted there. The standard itself gives 0.55 in an informative note and says no single limit value is provided for that category. So 0.42, a figure for floors wet with water, is not the standard's benchmark for a greasy cook line.
Other test names on data sheets
| Document | What it is | Worth knowing |
|---|---|---|
| ASTM E303 | Test method using the British Pendulum Tester, in the lab or in the field. | Values do not necessarily agree or correlate with other slipperiness measuring equipment. |
| ASTM D2047 | Laboratory test of static coefficient of friction on polish-coated flooring, using the James Machine. | Not intended for wet surfaces. Its 0.5 figure is only appropriate for polish-coated surfaces tested with this machine. |
| ASTM F2508 | Practice for validating walkway tribometers, instruments that measure floor friction, against reference materials. | Not intended to establish a safe threshold value for any walkway surface. |
| NFSI B101.1 and B101.3 | National Floor Safety Institute test methods for wet static and wet dynamic coefficient of friction. | NFSI says it was an ANSI-accredited standards developer from 2006 to 2019 and became independent in 2020. |
Sherwin-Williams's guide says there is no consensus on which test method is best or most accurate.
What a number on a data sheet tells you
A slip-test number describes the sample that was tested. Pin down five things before relying on one.
- Which test. Results from different methods are not interchangeable. ASTM E303 says as much about its own.
- Wet or dry. Fosroc notes that a dry-floor result does not apply to the same surface when wet. One Sika epoxy quartz sheet lists a coefficient of friction of 0.6, citing "ANSI 326.3", and does not say on that line which it was.
- What was on the floor. The A326.3 wet figure is about water. Oil, grease and fats are a separate category.
- Which build. A result belongs to one aggregate, one broadcast rate and one top coat. Fosroc bases its ratings on the maximum recommended aggregate and says other rates give other ratings.
- New or worn. Fosroc says its tests are run on newly coated surfaces and do not account for wear. The Plant Services article says surfaces in constant use erode, so a textured floor needs periodic recoating and renewed texture.
The makers' answer is a sample. LATICRETE's quartz sheet requires mock-ups and field test areas to validate properties including coefficient of friction. Sherwin-Williams says a sample should always be obtained and tested before a slip-resistant floor is installed.
Changing the texture later
Texture can be renewed. Sherwin-Williams's prep guideline says existing seamless floors are resealed or resurfaced from time to time because of wear or to change the skid resistance, and that an existing epoxy floor is cleaned, degreased and mechanically abraded first. The Construction Specifier says MMA accepts a fresh top coat at any later date without mechanical preparation.
What to ask the installer
- Can I see and walk on a sample panel or mock-up of this exact build, wet?
- Which aggregate, what size, how heavy a broadcast, and how many top coats over it?
- What slip-test result exists for that build? Which method, wet or dry, and with what on the surface?
- For a kitchen: has the maker declared the product for areas with oil and grease?
- How does this texture change cleaning, and what does the maker's maintenance guide call for?
- When the texture wears, how is it renewed, and how long is the area out of use?
Sources
- OSHA, 29 CFR 1910.22, Walking-Working Surfaces: General requirements (2016)
- OSHA, interpretation letter, Static coefficients of friction for walking/working surfaces (2003, archived)
- Tile Council of North America, Dynamic Coefficient of Friction and ANSI A326.3
- Tile Council of North America, Dynamic Coefficient of Friction: Frequently Asked Questions
- Tile Council of North America, ANSI A326.3-2021, full standard (released February 2022)
- Sherwin-Williams, A Guide to Slip Resistance for Resinous Flooring
- Sherwin-Williams, Slippery Floor Solutions for Commercial & Industrial Facilities
- Sherwin-Williams, Striking the Balance: Slip resistance, cleanability, and durability in resin flooring
- Sherwin-Williams, Concrete Surface Preparation guideline, Form G-1 (02/26)
- Stonhard, Achieving Slip Resistance with the Diverse Textures of Resinous Floors (2024)
- Sika, Sikafloor Pronto RB-1823 CQ system data sheet (2025)
- Sika, Sikafloor DecoDur Quartz FX system data sheet (2026)
- Sika, Sikafloor White Paper: Slip Resistant Floors in Food & Beverage Facilities (2026)
- LATICRETE, SPARTACOTE Blended Quartz data sheet DS-87.2 (2026)
- Fosroc, Technical Bulletin: Slip Resistant Flooring using broadcast aggregates (2026)
- Floorguard Products, Technical Reference Sheet 57: Anti-Slip Additives for Resinous Coatings
- Plant Services, Selecting and maintaining textured floors (2003)
- The Construction Specifier, Best practices for specifying resinous flooring systems (2021)
- ASTM E303-22, Measuring Surface Frictional Properties Using the British Pendulum Tester
- ASTM D2047-25, Static Coefficient of Friction of Polish-Coated Flooring Surfaces as Measured by the James Machine
- ASTM F2508-23, Validation of Walkway Tribometry Using Research-based Reference Materials
- National Floor Safety Institute, NFSI Standards
Keep reading
- Cleaning and maintenance: looking after the floor once it is in.
- Food rules for floors: what Minnesota and federal food rules say about a floor.
- Glossary: the words on a flooring bid, in plain English.
You reach the owner, the same person who looks at the floor, prices the job and runs the install. How this works.